Victron Nucleo GX — 5.8. VE.Can Resistive Tank Sender Adapter

Nucleo GX Manual Important VE.Can and BMS-Can must not share the same bus If both are needed, use a GX device with two separate CAN buses (e.g. Cerbo GX MK2 or Ekrano GX) Port configuration Access via Remote Console: Settings → Connectivity → VE.Can port 1 / 2 → CAN-bus Profile Default settings: VE.Can: 250 kbit/s Notes Some BMS units use CANbus BMS profile at (250 kbit/s). Connect these to a VE.Can port and set the appropriate profile VE.Can & CAN-bus BMS (250 kbit/s). Only use batteries listed on Victron’s compatibility list to ensure proper communication. Others are not supported. 5.5.

Inverter RS, Multi RS and MPPT RS The Inverter RS, Inverter RS Solar, and Multi RS are equipped with both VE.Direct and VE.Can interfaces. However, for these products: A GX device must be connected via VE.Can. VE.Direct cannot be used to connect these devices to a GX system. The VE.Direct interface on these models is intended solely for programming, using a VE.Direct to USB adapter. Exception: MPPT RS The MPPT RS can be connected to a GX device via either VE.Direct or VE.Can, depending on system requirements and available ports. 5.6. BMV-600 series Connect the BMV-600 using the VE.Direct to BMV-60xS cable. (ASS0305322xx). 5.7. DC Link Box Connect the DC Link Box with the supplied RJ12 cable.

Then connect the BMV-700 to the NGX. 5.8. VE.Can Resistive Tank Sender Adapter See the VE.Can resistive tank sender adapter manual for details about the adapter. Connection guidelines Use a standard RJ45 UTP cable to connect the adapter to a VE.Can network. Terminate the VE.Can network at both ends using VE.Can terminators. A bag with two terminators is included with each VE.Can product. Additional terminators are available separately (Part No. ASS030700000). Ensure that the CAN-bus is powered. Refer to the Power chapter in the Tank Sender Adapter manual for details. Page 27 Connecting Victron products