Victron Nucleo GX — 6.12. Connecting a SmartSwitch DC4

Nucleo GX Manual 6.12. Connecting a SmartSwitch DC4 The SmartSwitch DC4 by Energy Solutions is a configurable, four-channel DC load controller. It is internally powered and features an isolated CAN interface, ensuring reliable integration into marine, mobile, and industrial systems. Features 12 V or 24 VDC operation CAN bus controlled 4 channels providing load control, lamp dimming and digital sensing User-definable current limiting Thermal overload protection On-module control and output status indication Output modes For full details, refer to the SmartSwitch DC4 manual, available on the product page . Each of the four channels can be configured in one of the following modes:

Latched - Toggle (on/off) output. Momentary - Output remains active only while the button is pressed. Dimming - Lamp dimming via 120 Hz pulse-width modulation (PWM). Installation VE.Can connection For physical and electrical installation instructions, see the Quick Start Guide available on the product page . GX device configuration Connecting supported non-Victron products Page 50 The SmartSwitch DC4 features two RJ45 connectors for VE.Can communication with the GX device. It can either be: • Looped through, when part of a chain of VE.Can devices, or • Terminated using an RJ45 terminator, if it is the final device in the VE.Can network.

Ensure that the SmartSwitch DC4 is connected to the VE.Can port on the GX device — not the VE.Bus port. SmartSwitch DC4 connected at the end of the VE.Can network SmartSwitch DC4 looped through