Victron Nucleo GX — 6.13. Connecting Safiery STAR Range

Nucleo GX Manual Grouping outputs 6.13. Connecting Safiery STAR Range The Safiery STAR Range of controllers are a configurable range of 3 products: 12 Channel 6 x 30 A and 6 x 10 A 12 Channel 4 x 10 A and 8 x 10 A Dimmable and RGBW 4 Channel 4 x 15 A Dimmable and RGBW Connecting supported non-Victron products Page 51 Once connected and powered, the SmartSwitch DC4 will appear in the Devices list on the GX device. The SmartSwitch device page displays: • Module state • Supply voltage • Channel state • Channel current • Channel mode A dedicated Setup menu allows configuration of each channel individually. On each individual channel page in the Setup menu, the following options are available:

• Custom name: Assign a custom name to the channel. (Note: the module name can be changed via the Device menu). • Group: Allocate the channel to a group. • Type: Select the output mode: Latching (Toggle), Momentary, or Dimmable. • Fuse rating: Set the fuse rating (2–5 A). Each channel can be grouped by assigning a group name on the channel’s setup page. Channels with the same group name are displayed together in a single group card on the Switch pane. This makes it easy to combine related outputs, for example, grouping all lighting channels under one tile. Channels without a group name will appear in a card labelled with the module name.