Victron Nucleo GX — 6.16. Reading generic alternator data from compatible NMEA 2000 DC sensors

Nucleo GX Manual 6.16. Reading generic alternator data from compatible NMEA 2000 DC sensors The GX device can read voltage, current, and temperature data from generic alternators when connected to compatible third- party NMEA 2000 DC sensors. Note: This data is used for display only. It is not used for system calculations or control functions. NMEA 2000 sensor requirements To ensure compatibility, the NMEA 2000 DC sensor must meet the following criteria: Most NMEA 2000 DC sensors are expected to work. Confirmed compatible devices Across Ocean Systems DC Current Sensors Physical connection to a GX device NMEA 2000 networks and GX devices use different connector types.

Two adapter solutions are available: 1. VE.Can to NMEA 2000 cable (Victron) Allows connection between a GX device’s VE.Can port and a standard NMEA 2000 network The internal fuse can be included or removed to allow or prevent Victron equipment from powering the NMEA 2000 network See voltage warning below. 2. 3802 VE.Can Adapter by OSUKL Ideal for connecting a single NMEA 2000 device (e.g. alternator sensor) to the VE.Can network Can provide 12 V power to low-voltage NMEA 2000 devices from a 48 V Victron system Voltage compatibility (24 V & 48 V Systems) While Victron GX devices tolerate up to 70 V on their CAN-bus interface, many NMEA 2000 devices do not.

Most require 12 V, and some tolerate only up to 30–36 V. If your system includes NMEA 2000 devices that cannot handle system voltage: Use the 3802 VE.Can Adapter (OSUKL), or • Use the VE.Can to NMEA 2000 cable without its fuse, and power the NMEA 2000 network separately using a 12 V NMEA 2000 power adapter cable (not supplied by Victron). The VE.Can port on the GX device does not require external power to operate. Connecting supported non-Victron products Page 59 Requirement Value Device Class 35 – Electrical Generation Device Function 141 – DC Generator DC Type Must be set to Alternator in PGN 127506 DC Details Data PGN 127508 – Battery Status (must transmit voltage, current, temperature)