Victron Energy Nucleo GX — Wiring the WS500 to VE.Can

Nucleo GX Manual 6.16.1. Wakespeed WS500 alternator regulator support Introduction The WS500 is an external smart alternator regulator with CAN-bus and NMEA 2000 communication, designed primarily for marine and RV applications. When connected to a GX device, the Wakespeed WS500 allows alternator performance monitoring and DVCC-based control. Requirements To integrate the WS500, the following conditions must be met: 1. Venus OS firmware v2.90 or later on the GX device 2. Wakespeed WS500 firmware 2.5.0 or later on the WS500 controller 3. The WS500 must be connected to the VE.Can port of the GX device. Connection via the BMS-Can port (e.g.

on Cerbo GX) is not supported for monitoring Requirements for DVCC control 1. Venus OS firmware v3.30 or later on the GX device 2. Wakespeed WS500 firmware 2.5.2 or later on the WS500 controller 3. The Wakespeed-supplied current shunt must be installed at the alternator 4. WS500 must be configured with "Shunt at Alternator" toggled on (Wakespeed application: System Tab on the Configuration screen) 5. Define the Alternator Capacity in Amps on the Alternator Tab 6. NMEA2000 Support (System > Expert Mode) must be enabled Wiring the WS500 to VE.Can Both the WS500 and VE.Can use RJ45 connectors for CAN communication, but with different pinouts.

A standard (straight) UTP network cable will not work. A custom crossover cable is required. Refer to the below diagram for pinout details: CAN pin mapping: VE.Can: pin 7 = CAN-H, pin 8 = CAN-L WS500: pin 1 = CAN-H, pin 2 = CAN-L Wiring requirement: Pin 1 (WS500) → Pin 7 (VE.Can) Pin 2 (WS500) → Pin 8 (VE.Can) Connect the end with pin 7/8 to the VE.Can port on the GX device. The other end (pin 1/2) connects to the WS500. Both ends must be terminated. Cable colours are not relevant when making the crossover cable yourself. Wakespeed also offers a pre-made cable with a blue RJ45 plug—this end connects to the VE.Can port.

Please note that the black terminators supplied by Wakespeed and the blue terminators supplied by Victron are not interchangeable. Therefore: insert the Victron terminator on the Victron side of the network, and insert the Wakespeed terminator into the Wakespeed. Connecting supported non-Victron products Page 60