Victron Nucleo GX — WS500 data on the VRM Portal

Nucleo GX Manual GX device user interface for WS500 Once connected, the WS500 appears in the GX device’s Device List. The WS500 menu then provides the following information and data: WS500 data on the VRM Portal The VRM portal can display WS500 data including current, voltage, and temperature. Currently 3 widgets are available on VRM VRM custom widget showing WS500 voltage, current and temperature Connecting supported non-Victron products Page 62 • Output: Voltage, current, and power reported by the alternator regulator • Temperature: Alternator temperature measured by the WS500 sensor • State: the charging state of the WS500 • Off: not charging • Bulk / Absorption / Float:

WS500 active using its own algorithm • External Control: charging controlled by a BMS (e.g. Lynx Smart BMS) • Network Status: • Standalone: operating independently • Group Master: providing charging targets to other WS500 units • Slave: receiving charging commands from another WS500 or BMS • Error: Displays current error state • Refer to the Wakespeed Configuration and Communications Guide for error codes • See appendix for error #91 and #92 • Field Drive: Percentage of field drive output to the alternator • Speed: Alternator RPM, derived from stator signal. If this is wrong, it can be adjusted by setting the Alt Poles option within the Wakespeed SCT configuration line • Engine Speed:

Engine RPM, sourced from: • Calculated from alternator speed and Eng/Alt ratio as set by the SCT configuration line • NMEA 2000 (PGN127488) • J1939 (PGN61444) You may assign a custom name to the WS500 via the Device Menu. This updates the regulator’s $SCN configuration line.