Nucleo GX Manual Troubleshooting & FAQ For further assistance and troubleshooting please contact Wakespeed support directly. Error code #91 and #92 All WS500 error codes, as defined in the Wakespeed Communications and Configuration Guide, are reported by the GX device. In systems with integrated BMS, the following errors are critical as long as the events are active and require immediate attention. #91: Lost connection with BMS The WS500 has lost communication with the BMS and will drop into the configured get home mode. As soon as communication is restored with the BMS, it will revert to following the charging goals as set by the BMS. #92:

ATC disabled through feature IN The BMS has signalled a charge disconnect event through the feature in wire and the WS500 has therefore reverted to an Off status. Current and power data are not displayed in the WS500 device menu The absence of current and power data in the WS500 device menu is not a fault. It reflects the system configuration and is expected under certain conditions: No alternator shunt installed: The WS500 cannot measure alternator output current and power without an alternator shunt. Alternator shunt installed but not properly configured: Check the ShuntAtBat setting and the Ignore Sensor setting using the Wakespeed configuration tools.

Note on alternator shunt An alternator shunt is a current sensor installed in series with the alternator output. It connects directly to the WS500 and provides real-time measurement of alternator output current and power. Optional: Not required for basic operation Mandatory: Required for DVCC compatibility If no shunt is installed, the GX device will still display parameters such as field drive (%) and alternator voltage, but not current or power. FAQ Q1: Is the alternator output current (if measured) used for anything beyond display purposes? A1: Yes.

DVCC integration allows the GX device to control the WS500’s output, distributing charge current between the WS500 and, for example, MPPTs and DC-DC battery chargers. Q2: Can the battery output current be read via CAN bus by a Lynx Smart BMS or other monitors? A2: Yes. When the WS500 shunt is configured to measure alternator output, the current can be read over CAN bus (e.g. by a Lynx Smart BMS). The WS500 uses this to avoid overcharging, e.g. if the battery requires 100 A and the WS500 provides 200 A, the extra 100 A is directed to DC loads. This improves load calculation accuracy. Q3: Are there wiring recommendations when using a Lynx Smart BMS or Lynx BMS NG? A3: Yes.

We provide detailed system examples, including: A catamaran setup with two WS500 units A system with a second alternator controlled by a WS500 These examples can be used as templates and are available on the product page of the Lynx Smart BMS . Q4: What if no Lynx Smart BMS is used, how should wiring be done? A4: Wakespeed offers a quick start guide covering DIP switch configuration and harness wiring. Additional wiring diagrams are included in the WS500 product manual . Note: the shunt must be connected to the battery, and the WS500 configured accordingly. Connecting supported non-Victron products Page 63