Nucleo GX Manual 6.16.2. Arco Zeus Alternator Regulator support The Arco Zeus is an external smart alternator regulator with CAN bus and NMEA 2000 communication, designed specifically for marine and RV applications. It is supported by Venus OS, including DVCC control, and enables monitoring and control of alternator performance via a GX device. When configured correctly, the Zeus follows the charge parameters set by the GX device and/or Lynx BMS. Requirements To integrate the Zeus with a Victron system, the following requirements must be met: 1. Venus OS firmware v3.50 or later 2. Arco Zeus firmware v1.25 or later is installed on the Zeus controller 3.
Connection via VE.Can port of the GX device. It is not possible to connect the Zeus to the BMS-Can port of a Cerbo GX. 4. Sync mode in the Zeus app must be set to 'Victron Follower' 5. An alternator shunt must be installed for proper DVCC operation. Refer to the Arco Zeus documentation. Installation Install the Arco Zeus regulator according to the Arco Zeus Bluetooth Alternator Regulator Installation Guide, available on the Arcomarine website . Connect the Zeus to the VE.Can port of the GX device using a standard Cat5/6 Ethernet cable Ensure the VE.Can network is properly terminated: Use a NMEA 2000 M12 terminator on the Zeus NMEA 2000 port.
Use a VE.Can RJ45 terminator on the GX device or Lynx BMS, depending on the network layout. Note: There are configurations where this is not necessary, for example, in a paralleled Lynx BMS battery system, where each battery bank has its own Zeus alternator regulator. Enable alternator shutoff via BMS: Connect a wire from the Lynx BMS “NO” relay output to the Zeus battery/control harness input labeled “Enable/ATC from BMS” This ensures the Zeus shuts off safely before the contactor opens, protecting the alternator from damage Zeus configuration Refer to the Arco Zeus Bluetooth Alternator Regulator Installation Guide for full configuration instructions, available on the Arcomarine website .
In the Zeus app, set Sync Mode to “Victron Follower” Set the ‘Alternator Max Output Current’ to a value appropriate for both the alternator and the battery. DVCC uses this value to determine the maximum available charging current. GX device configuration On the GX device (via Remote Console): Navigate to Settings → Connectivity → VE.Can port [1 or 2] Set the CAN-bus profile to “VE.Can (250 kbit/s)” Lynx Smart BMS or Lynx BMS NG configuration Set the BMS relay mode to “Alternator ATC”. This ensures the ATC opens first, followed by the contactor after 2 seconds, giving the Zeus time to shut down before the battery is disconnected.
Monitoring Once the Arco Zeus controller is connected to the GX device, it will appear in the Device List with an entry for the alternator regulator. Available information and parameters: Output: Displays alternator output voltage, current, and power as reported by the Zeus. Temperature: Shows the alternator temperature, measured via the Zeus temperature sensor. State: Indicates the charging state of the Zeus: Connecting supported non-Victron products Page 64