Nucleo GX Manual Off - Not charging Bulk, Absorption, or Float - When using its internal charging algorithm External Control – When controlled externally by a BMS, such as the Lynx Smart BMS Network Status: Displays Standalone when the regulator is operating independently. Field Drive: Indicates the percentage of field drive being applied to the alternator via the field connection. Speed: Shows the alternator speed in RPM, measured via the stator feed. Engine Speed: Displays engine RPM, determined by:
Calculation based on alternator speed and the engine-to-alternator drive ratio (as set in the Zeus app) NMEA 2000 (PGN127488), if engine RPM is broadcast over NMEA 2000 J1939 (PGN61444), if engine RPM is received via J1939 Device: Contains product-specific and connection-related information. The Arco Zeus data that can be displayed on the VRM portal is current, voltage and temperature. Troubleshooting For further assistance and troubleshooting please contact Arco Zeus support directly. 6.16.3. Revatek Altion Alternator Regulator Support The Revatek Altion is an external smart alternator regulator with CAN bus support for VE.Can, NMEA 2000, and RV-C protocols.
Designed for marine and RV applications, it integrates with Victron GX devices to enable full alternator monitoring and control. Supported Altion devices Altion Altion Max Requirements Altion firmware v20250316 or later Venus OS v3.50 or later Installation, configuration and troubleshooting Refer to the official Revatek Altion User Guide for detailed instructions on installation, configuration, and troubleshooting. The guide is available from Revatek. Connecting supported non-Victron products Page 65