Victron Nucleo GX — 6.17.4. How to configure the Victron GX device

Nucleo GX Manual 6.17.3. How to connect a Curtis E/SE series controller to a Victron GX device CAN bus connection Use a modified RJ45 cable with the following pin assignment: CAN termination To enable CAN termination on the controller: Connect CAN TERM H (Pin 21) and CAN TERM L (Pin 34) together Curtis E/SE series support Tested with Curtis 1232 SE and 1234 E Expected to work with other 123X E/SE series controllers 6.17.4. How to configure the Victron GX device Requirements Venus OS version 3.70 or later is required. Configuration Troubleshooting If no controllers are found:

Verify CAN bus wiring and termination Verify the selected CAN-bus profile matches the controller baud rate Connecting supported non-Victron products Page 69 Role RJ45 pin number Controller pin CAN Ground 3 (Green/White) 7 CAN High 7 (Brown/White) 23 CAN Low 8 (Brown) 35 1. Configure CAN bus profile • Go to: Settings → Connectivity → → CAN-bus profile • Select one of the following: • VE.Can & CANopen E-drive (250 kbit/s) Choose this profile if the motor controller shares the same VE.Can network as other VE.Can devices. • CANopen E-drive (500 kbit/s) Use this profile if the motor controller is connected to a dedicated CAN bus. 2. Scan for motor controllers • Go to:

Settings → Connectivity → → CANopen E-drives • Ensure the following: • The motor controller is correctly connected to the GX device VE.Can port • The motor controller is powered on • Press Scan to detect connected motor controllers. The CANopen node IDs of detected controllers will be shown under Discovered E-drive IDs. Detected controllers are retained after reboot or firmware update.