Victron Nucleo GX — 9.1. Menu structure and configurable parameters

Nucleo GX Manual Page 84 Configuration Item Default Description DNS server Displays the IP address of the DNS (Domain Name System) server used to resolve domain names into IP addresses. Settings → Connectivity → Bluetooth (for VictronConnect App) Bluetooth (for VictronConnect App) Enabled Switch to enable or disable the built-in Bluetooth interface. Pincode: For GX devices with serial numbers before HQ2242, the default PIN is 000000. For HQ2242 or later, a random 6-digit PIN is printed on the label on the back of the device. Settings → Connectivity → Mobile Network Mobile Network No cellular modem connected Submenu with options to configure a connected GX GSM or GX LTE 4G modem.

Read full feature description. Settings → Connectivity → VE.Can port VE.Can port 1..2 (if applicable) VE.Can (250 kbit/s Submenu to configure the CAN-bus profile for the VE.Can port(s). Available options include: Disabled, VE.Can (250 kbit/s), VE.Can & CAN-bus BMS (250 kbit/s), VE.Can & CANopen E-drive (250 kbit/s), CAN-bus BMS LV (500 kbit/s), Oceanvolt (250 kbit/s), RV-C (250 kbit/s), CANopen E-drive (500 kbit/s). Additional options include: Devices, NMEA2000-out, Unique Identity Number Selector, Check Unique ID Numbers, and Network Status. Settings → VRM - Read full feature description [114] VRM Portal Full This setting determines the system’s connection to the VRM portal:

• Off – No connection to VRM • Read-only – Allows monitoring but no remote setting changes or firmware updates • Full – Enables full remote access and management VRM Portal ID Use this ID string when registering the GX device on the VRM Portal. VRM Device Registration Contains a link and/or QR code for device registration on the VRM Portal. VRM device instances Provides the device instances for every device connected to the GX. Devices are grouped by service type (e.g. battery monitor, solar charger, AC load) and sorted alphabetically within each group. Instance numbers only need to be unique within the same service type, the same instance number on different device types is not a conflict.

Log interval 15 minutes Set the interval between data logs to any value from 1 minute to 1 day. For systems with unstable connections, a longer interval is recommended. Use secure connection (HTTPS) 15 minutes Encrypts communication between the GX device and the VRM server using HTTPS for secure data transmission. Last contact Displays the time elapsed since the GX device last communicated with the VRM server. Connection status No error Shows the current status of the VRM connection. If there is a communication error, it will be displayed here. See here for more details on troubleshooting VRM errors.

[116] Reboot device when no contact Disabled When enabled, the GX device will automatically reboot after a set delay if the internet connection is lost. This can help resolve temporary networking issues. No contact reset delay (hh:mm) 01:00 Defines how long the GX device must be offline before it automatically restarts to restore connectivity. Storage location Internal storage Indicates whether data is being stored on the internal memory or an external device such as a USB drive or microSD card, if mounted.