Victron Nucleo GX — 9.1. Menu structure and configurable parameters

Nucleo GX Manual Page 85 Configuration Item Default Description Free disk space Displays the amount of available storage space on the current storage device. microSD / USB Use this option to safely eject a connected microSD card or USB storage device before removal. Removing it without ejecting may result in data loss. Stored records Displays the number of data records stored locally while the device is offline. The GX device will upload these records automatically once the internet connection is restored. Oldest record age Indicates how old the oldest locally stored record is, in cases where the GX device has been unable to connect to the internet or VRM.

Settings → Integrations → PV Inverters - Read full feature description Inverters Displays connected AC PV inverters. Position AC Input 1 AC input 1, AC input 2, AC Output Phase L1 Show Yes Dynamic power limiting Enabled The PV inverter has support for power limiting. Disable this setting if it interferes with normal operation. Find PV inverters Scan for available PV inverters. Detected IP addresses Displays the IP address of PV inverters that have been discovered. Add IP address manually If an inverter has a manually assigned IP address, you can add it directly here.

Automatic scanning This setting will continue to look for PV inverters, this can be useful if using a DHCP assigned IP address that might change. Modbus port and unit ID settings Submenu where port and unit ID can be added. Settings → Integrations → Energy Meters via RS485 - Read full feature description Role Grid meter Define the role of the energy meter. Available options: Grid, PV inverter, Generator, AC load, EV Charger, Heat pump Phase type Single phase Select the phase type of the system to be measured: either single- phase or multi-phase. Settings → Integrations → Modbus Devices Automatic scanning Enabled Scans automatically for Modbus TCP/UDP devices.

Scan for devices Press to scan Manually trigger a scan for Modbus TCP/UDP devices. Saved devices Displays a list of found Modbus TCP/UDP devices and their IP address. Discovered devices Displays a list of discovered Modbus TCP/UDP devices. Use this menu to activate these devices. Settings → Integrations → Bluetooth Sensors Enable Disabled Enable this option to scan for supported Bluetooth sensors. Enable to scan for supported Bluetooth sensors. Discovered sensors are listed with a slider to activate them. Continuous scanning Disabled Forces continuous scanning for supported Bluetooth sensors. May interfere with WiFi operation.

Bluetooth adapters Lists built-in and connected Bluetooth adapters with their MAC addresses. Settings → Integrations → Tank and Temperature Sensors Tank level input (number depends on device) Disabled Enable to display the tank level inputs in the Devices list.