Nucleo GX Manual Page 86 Configuration Item Default Description Temperature input (number depends on device) Disabled Enable to display the temperature inputs in the Devices list. Settings → Integrations → Relays Function (Relay #) Alarm relay Selects the function assigned to the relay. Available options include: Disabled, Alarm relay, Genset start/stop, Connected genset helper relay, Tank pump, Temperature, and Manual. When the relay is set to manual mode, a slider is displayed that allows you to turn the relay on or off manually. Polarity (Relay #) Normally open Sets the relay polarity on the back of the GX device. Options are Normally open or Normally closed. Note:
Using Normally closed increases the power consumption of the GX device. Settings → Integrations → Digital I/O GX Built-in - Digital input # Disabled Controls the function of digital inputs. Available options include: Disabled, Door alarm, Bilge pump, Bilge alarm, Burglar alarm, Smoke alarm, Fire alarm, CO₂ alarm, and Generator. On specific GX devices, additional options such as Touch input control and Pulse meter are also available. Settings → Integrations → MQTT Access MQTT Access Disabled MQTT access only needs to be enabled when integrating a third party device or service like Home Assistant which requires access to the MQTT broker over the local network.
Settings → Integrations → Modbus TCP Server Modbus TCP Server Submenu to enable Modbus TCP and grant access permissions. Enable Modbus TCP Server Disabled This setting enables the ModbusTCP service. More information about ModbusTCP in this document and in the communications white paper https://www.victronenergy.com/upload/documents/Whitepaper- Data-communication-with-Victron-Energy-products EN.pdf _ Access permissions Write allowed Defines whether Modbus clients have read-only access or are also allowed to write values. Available services Lists all available services together with their Unit ID.
Settings → Integrations → Venus OS Large Features Signal K Enable to start the integrated Signal K server. Node-RED Enable to start the integrated Node-RED environment. Venus OS Large Documentation Link to the Venus OS Large documentation. Victron Community Link to the Victron Community. Settings → System Setup Settings → System Setup → System name System name Automatic Select the system name - presets or user defined. Settings → System Setup → AC System AC input 1 Generator Select Not available, Generator, Grid or Shore power. Note: additional configuration is required for complete setup of these options. AC input 2 Grid Same choices as above. Position of AC loads AC output only Options:
• AC input only – The AC output of the Inverter/Charger is not used. • AC output only – All AC loads are connected to the output of the Inverter/Charger. • AC input & output – The system automatically displays loads on the input of the Inverter/Charger if a grid meter is present. Loads on the output are always displayed.