Nucleo GX Manual Page 91 Configuration Item Default Description Start level 50% Defines the tank level at which the pump will start (relay closes). When the measured level falls below this value, the pump is activated. Stop level 80% Defines the tank level at which the pump will stop (relay opens). When the measured level rises above this value, the pump is deactivated.
Settings → Devices → Shelly AC Phase [L1..L3] Displays the voltage (V), current (A) and power (W) per phase AC Totals Displays the combined power (W) and energy (kWh) across all phases Energy [L1..L3] Displays the imported (consumed) energy in kWh for each phase Reversed Energy [L1..L3] Displays the exported (generated/fed-back) energy in kWh for each phase Setup Submenu to configure the device role (e.g. Grid meter, PV inverter, AC load, Genset), its position in the system, and the phase assignment Outputs Submenu to configure each output channel:
assign a name and group, select switch type, set the function, and enable or disable the show controls option Device Displays product name, firmware version, connection details, and other device information used for diagnostics