TwinCAT NC Axes Parameterization of the KL2521 The base frequency 1 is to be set so that the terminal creates the maximum frequency when fully driven for the application concerned. If too low a value is entered here then the axis does not reach the foreseen velocity. If the setting is too high the resolution is worse than it was possible with the high resolution terminal. If this is acceptable then at least limits have to be ensured with by corresponding settings, so that the axis does not travel at too high velocity. The terminal’s operating mode is to be set as per the signal definition of the power section. In this example, a direction signal and a pulse is expected.
The reference frequency for the example shown in figure 2 is calculated with the formula BF = N * S / 60. Here BF is the frequency in Hertz, N the speed in RPM and S the step number of the motor in the selected operating mode. Sample calculation: BF = 1200 [RPM] * 200 [1/R] / 60 [s/min] = 4000 Hz The following example shows the correct setting for this example. Numerical Control (NC) Basics 24 Version: 1.2