TwinCAT NC Axis components Referencing parameters SERCOS Axes The modulo scaling (only in the weighting of the position data in the modulo display (S-0-0076 bit 7)) determines the modulo value at which the position data begins again at 0. This value must agree with the value set at the drive (S-0-0103) if the position is to be correctly indicated and controlled. When TwinCAT is active and SERCOS is at least in Phase 2, the value can be read off via "Calculate". Download and Upload can be used to write or read the value to and from the running TwinCAT system. 5.2 Drive The drive transfers the output voltage to the motor's power section. A wide variety of drive versions is supported.
Servo drives, a high/low speed drives, and stepper motor drives are available. The drive parameters include the motor polarity and the reference speed. Numerical Control (NC) Basics 34 Version: 1.2 Parameter Data type Unit Description Search direction for referencing cam inverted BOOL Search direction inverted: FALSE = cam is looked for in the direction of positive movement. TRUE = cam is looked for in the direction of negative movement. Search direction for sync pulse inverted BOOL Search direction inverted: FALSE = synchronization pulse is looked for in the direction of positive movement. TRUE = synchronization pulse is looked for in the direction of negative movement.
Reference position float mm The axis position that is assigned to the synchronization pulse that is active during homing. If the actual position of the axis is acquired in any unit other than mm, then that unit must be used here too. External sync pulse BOOL Reserved