TwinCAT NC Axis components Master generator: Asynchronous The generator for reaction to asynchronous instructions (override, new end position, position compensation etc.) checks the parameters of the instruction as well as whether the instruction is permissible in the current operating state, and initiates execution of the instruction the next time the SAF is called. This implies that final knowledge as to whether the instruction has indeed been initiated does not exist until after this SAF call. Slave generator:
SVB The SVB slave generator checks whether the coupling is permitted and whether a start is permitted in the current operating state of the axis, checks the coupling parameters and sets global start parameters. When these actions have been successfully completed, it couples the slave logically to the master. Slave generator:
SAF Each time the task is called, the SAF master generator calculates, from the local set values of the master axis (which can, in turn, be a slave axis) and the coupling factor, the local set values for position (for the position controller), velocity with arithmetic sign (for the velocity feed forward), acceleration (for a controller with acceleration feed forward), direction (for the feed enable, which depends on the direction). Slave generator:
asynchronous The generator for reaction to asynchronous instructions (position compensation, online decoupling etc.) checks the parameters of the instruction as well as whether the instruction is permissible in the current operating state, and initiates execution of the instruction the next time the SEC task is called. This implies that final knowledge as to whether the instruction has indeed been initiated does not exist until after this SEC call. Slave generator:
flying saw Because of the wide variety of its functions, the flying saw has its own type of set value generator, consisting of an SPP master generator working together with an SEC master generator in the waiting and synchronization phase. In the synchronous phase, the flying saw has an SEC slave generator. This can be converted into either an initialized SEC braking generator (in the stop phase) or (decoupled) online into a suitably initialized SEC master generator. 5.5 Input/Output There are input/output connections for channels, axes, encoders and drives. Input/Output for NC channels Standard channels, in other words channels for PTP axes, do not require any input/output connections.
These are only required for interpreter channels. A variable of type PLCTONC_CHANNEL is to be created in the PLC for each channel. These variable(s) must be associated with the NC channel variables Channelx_FromPlc (to be found under channel inputs). A variable of type NCTOPLC_CHANNEL is to be created in the PLC for each channel. These variable(s) must be associated with the NC channel variables Channelx_ToPlc (to be found under channel outputs). These variables are required to allow signals to be exchanged between the NC and the PLC. The following data is exchanged here:
NC block skipping interpreter working mode interpreter status and error codes channel overrides and program numbers M-functions as flying signal bits and as handshake Numerical Control (NC) Basics 41 Version: 1.2