TwinCAT NC Axis components It is not normally necessary to associate the individual variables The description of the cyclic channel interface can be found in the appendix to the NC I . Input/output for axes A variable of type NCAXLESTRUCT_FROMPLC is to be created in the PLC for each axis. These variable(s) must be associated with the NC axis variables Axisx_FromPlc (to be found under axis inputs). A variable of type NCAXLESTRUCT_TOPLC is to be created in the PLC for each axis. These variable(s) must be associated with the NC axis variables Axisx_ToPlc (to be found under axis outputs). These variables are required to allow signals to be exchanged between the NC and the PLC.
The following data is exchanged here: controller and direction-dependent feed enables calibration cams calibration status positioning mode error codes and miscellaneous axis status information axis overrides coupling status It is not normally necessary to associate the individual variables A description of the interfaces is to be found under cyclic axis interface from PLC to NC [ } 53] cyclic axis interface from NC to PLC [ } 46] cyclic interface from NC to encoder and drive [ } 43] Input/output for encoders Every encoder that is not of the "simulation" type must be associated with an actual value acquisition module.
It is necessary to ensure here that the types in use are compatible with one another. A suitable type of encoder must be chosen. cyclic interface from NC to the encoder [ } 43] Input/output for drives Every drive that does not belong to a simulated axis must be associated with a set value output module. It is necessary to ensure here that the types in use are compatible with one another. A suitable type of drive must be chosen. cyclic interface from NC to the drive [ } 43] Numerical Control (NC) Basics 42 Version: 1.2