Axis commissioning Finally, the encoder values (position, speed, acceleration) can be filtered, which is of particular significance for encoder axes. WARNING Risk of injury and damage due to incorrect behavior of the controller Filtering the position, even if small values are used, can result in disastrously incorrect controller behavior. Always proceed carefully with the settings. 6.3 Drive and voltage output WARNING Unpredictable behavior of the axis under special circumstances Inform yourself about the behavior of the drive in case of overload. There are drives that automatically shut down when overloaded, so that the axle could then be force-free, full of energy and no longer braking.
Determination and setting the most important drive parameters: drive polarity, reference output, reference velocity, drift compensation. Interface The drive parameters are accessed via the System Manager. The drive parameter: determination of the direction 1. Use the encoder! Restrict the distance of travel using the software limit position min / max on the global tab for the axis. 2. On the drive's global tab, adjust the output limit to +1.0 or -1.0 . 3. On the controller's global tab, set a value of 1.0 for the feed forward weighting. 4. If the controller has a PID tab, set the position control factor Kv (and all other control factors) to zero. Deactivate the automatic offset adjustment.
5. If the drive has an analog tab, set the reference speed in accordance with the information provided by the machine manufacturer to something in the region of the correct value, and set the reference output to 1.0 . Set the drift compensation to zero. 6. On the global tab for the axis, set the same value for the maximum permitted speed as for the drive's reference speed . Set one tenth of this value under manual speed max and manual speed min . 7. If the controller has a PID tab, set the position control factor Kv (and all other control factors) to zero. Deactivate the automatic offset adjustment. 8.
Now use the and keys in the online image of the axis to move in the "smaller" and "larger" directions, and observe the machine. If, when the key is pressed the machine moves in the "larger" direction, and when the key is pressed it moves in the "smaller" direction, alter the motor polarity on the drive's global tab, and repeat this step. The drive parameter: feed forward This section is only necessary if the drive has an analog tab. 1. On the controller's global tab, set a value of 1.0 for the feed forward weighting. 2. On the drive's global tab, adjust the output limit to +1.0 or -1.0 . 3. On the controller's PID tab, set the position control factor Kv to a low value.
When correctly set, it will be easy to detect the following error during the test transits that are to be made out, but it will be constant. Example: 1 (mm/sec)/mm or 60 (mm/min)/mm. 4. On the drive's analog tab, set the reference speed to an approximately correct value in accordance with the information provided by the machine manufacturer. Set the drift compensation to zero. In accordance with the information provided by the machine manufacturer, set the reference output to 1.0 if this refers to 100% (or 10 Volts). If the figure provided is, for example, for 90% (or 9 Volts), 0.9 should correspondingly be set. 5.
On the global tab for the axis, set the maximum permitted speed to about 90% of the drive's reference speed . Set one tenth of this value under manual speed max and manual speed min . Numerical Control (NC) Basics 61 Version: 1.2