beckhoff TwinCAT 2 — 6.5 Axis parameters, axis monitoring and axis calibration

Axis commissioning 6.5 Axis parameters, axis monitoring and axis calibration Determination and setting the most important axis parameters: maximum velocity, following error monitoring, end position monitoring and those for dynamic behaviour and calibration. Interface The axis parameters are accessed via the System Manager. General axis parameters A variety of further parameters can be adjusted on the global tab for the axis. These determine the behaviour of the axis. A range of monitoring functions and status signals are also controlled here. You can specify the level to which all commands sent to the axis can be limited with the maximum velocity .

You should set a value here of about 90 to 95 % of the maximum velocity of the drive. The remaining control capacity is required for the controller in order to ensure correct positioning. When an NC interpreter is used, certain commands will cause the axis to be positioned using an adjustable control for the high-velocity travel . Not more than about 90% of the maximum velocity of the axis should be chosen here. The min and max manual operation velocities can be freely chosen, and largely depend on the ”confidence” of the user. In practice it has been found appropriate to set these velocities with a ratio of about 1 to 5 . The values must, of course, be smaller than the maximum velocity.

The reference travel velocity in the positive direction is only effective on axes with incremental encoders. This is the velocity with which the axis moves when looking for the calibration cam. The direction is set on the encoder's incremental tab. The reference travel velocity in the negative direction is only effective on axes with incremental encoders. This is the velocity with which the axis moves when leaving the calibration cam and when looking for the synchronisation pulse. The direction is set on the encoder's incremental tab. The positive / negative direction pulse widths specify the distances to be travelled by the PLC when the axis starts in the corresponding movement modes.

Fuller information is found in the PLC's function block descriptions. You can activate and set the position of a movement limit ( software limit switch ) both below and above. The following error (the difference between the set and actual positions) is continuously determined for axes with an analog tab (i. e. not for high/low-speed or for stepper motor axes). An adjustable threshold for monitoring these values can be activated. It is possible here to specify a filter time which may prevent an alarm being signaled if the threshold is briefly exceeded, for instance, during acceleration or braking.

Two independent windows can be specified around the target position of a movement ( target position windows ). Any size can be chosen for the windows. This makes it possible to create a signal for the PLC at any desired distance from the target. One of these windows also offers a filter time. The signal is only generated if the axis remains continuously within the window for whatever period is set there. It is possible for high/low speed axes to approach each destination always from the same direction, and having covered a minimum travel distance. This allows a greater precision to be achieved if the axis does not behave symmetrically, or if there is mechanical play.

This behavior can be activated, and the travel distance can be specified. The arithmetic sign of the specified distance determines the direction. In servo axes " reverse backlash compensation " can be used to compensate for mechanical play in the axes. The value entered here as the "reverse backlash" specifies the distance by which a target is exceeded. The arithmetic sign of the value specifies the direction of the overshoot. If the reverse backlash is positive, the target is only overshot when moving in a positive direction. Movement in the direction of smaller positions is not affected. Negative reverse backlash results in the opposite behavior. Numerical Control (NC) Basics 64 Version:

1.2