omron · 2 pp.

omron NXR EtherCAT IO LINK Quick Switch Feature Guide 202403

Related manuals

Document text

Quick Switch Feature – Reference Sheet NXR-ILM08C-ECT: EtherCAT ® Remote IO with IO-Link OMRON Corporation Industrial Automation Company i Empowering People Through Automation

Page 1

Quick Switch Feature - Reduce costly downtime by performing maintenance and setup without a PC *Port settings are reflected only after the NXR is power cycled 01 ~ 255 (Hex) Default 00 is for software Node address setting • Example: Switch in position 4 results in 4 inputs on ports 1-4 *The actual position of the hardware switch can be detected via CoE messaging to reduce the risk of setting mistakes. • Switch 0: Default setting. A user can set the ports normally through software • Switches 1-9: Correspond to the # of Inputs and input locations. Switch 9 is for all outputs. • Switches A-F: IO-Link mode - Compatible with any IO-Link input device up to 20 Bytes PDO size • Switches B, D, and F:

Digital Outputs on pin 2 to provide power to NXR hubs set in output mode i Empowering People Through Automation

Page 2