omron — 3-3-7 Teaching Positions

3 Implementation Example of Static Pick-and-place Equipment 3-3 Programming and Simulation Procedures 3 When teaching positions to the robot, you must store the position data of the robot in the V+ position variables. Here, create the following position variables. 3-3-7 Teaching Positions This section describes the procedure to manipulate the tool center point of the robot with the mouse in the 3D Visualizer. This operation is suitable for determining rough position and posture, because the tool center point of the robot moves to follow the mouse cursor, enabling intuitive robotic operation. 1 Select 3D Visualizer from the View menu on the main window of the Sysmac Studio.

The 3D Visualizer is displayed on the right side of the main window. 3-67 NJ-series Robot Integrated System Startup Guide (O049) Variable name Data type Application Corresponding IEC variable gl.pick Location Has the data of workpiece pick-up position. eLoc pick _ gl.place Location Has the data of workpiece place position. eLoc place _ gl.wait Location Has the data of robot wait position. eLoc wait _ Manipulating the Robot with the Mouse in the 3D Visualizer