Orion-Tr Tr Smart DC-DC Charger Non-Isolated — 7.3.5. Insufficient alternator power

Orion-Tr Smart DC-DC Charger Non-Isolated To find out what the state of charge (SOC) of the battery is, check the battery monitor (if present), or alternatively, check the charge stage the is in. 7.3.4. Battery cable voltage drop If there is a voltage drop over the battery cables, the will output the correct voltage, but the batteries will receive a lower voltage. Battery charging will take longer, potentially leading to undercharged batteries. In case there is a large voltage drop, the battery cables and cable connection will need to be checked, and if there are issues, they will need to be rectified. The voltage drop can have the following causes:

Battery cables with insufficient cross-sectional area Badly crimped cable lugs or terminals Loose terminal connections Bad or loose fuse(s) Battery cable voltage drop check This check can only be performed if the is in the bulk charge stage and is charging with full current. 1. Measure the voltage on the battery terminals of the using the VictronConnect app or a multimeter. V V or or 2. Measure the battery voltage on the terminals of the batteries using a multimeter. V V 3. Compare the two voltages to see if there is a voltage difference. The can only deliver its full output when the alternator supplies enough power to the input battery.

If the alternator cannot keep up, the input voltage collapses as soon as charging starts, and the charger will reduce or stop charging. Because the charger detects a running engine by the input voltage, an overloaded alternator can look identical to a stopped engine. 7.3.5. Insufficient alternator power Typical indications of insufficient alternator power: The input voltage drops sharply as soon as charging starts, and recovers as soon as charging stops. Monitor the input voltage in the VictronConnect app, or measure it at the charger's input terminals, with the engine running. Charging repeatedly stops with the message "Charge disabled:

Engine shutdown detected" although the engine is running. The sagging alternator voltage falls below the shutdown voltage, which the charger interprets as an engine stop. Charging cycles on and off: after charging stops, the input voltage recovers above the start voltage, charging restarts, pulls the voltage down again, and so on. The battery does not reach full charge despite sufficient engine running time. Possible causes: The alternator delivers less than its rated output. At idle speed, alternator output can drop to roughly 50% of the rating, and a hot alternator reduces its output further. A worn or slipping belt might have a similar effect.

The charger, or a combination of chargers, is oversized for the alternator. Each charger draws its full input current regardless of what the alternator can supply. This is particularly relevant when several units are connected in parallel. Page 20 Troubleshooting & Support