US Army Developmental Test Command TOP 1-2-621 — REPORT DOCUMENTATION PAGE

Downloaded from https://www.everyspec.com TOP 1-2-621 6 February 2009 (5) Start the wind machine, then the sand injection system and maintain conditions for 90 minutes. (6) After the completion of 90 minutes of exposure, stop the sand injection system and wind machine. (7) Rotate the UUT so as to expose the second face to the environment. (8) Repeat steps (5) through (7) until all faces or other points of interest have been exposed to the environment. (9) If operational checks are required, operate the UUT during the last 10 minutes of the last exposure to the environment. Otherwise, operational checks and visual inspections are performed at the end of the exposure.

Ensure personnel operating the UUT are wearing the proper personal protection equipment when in direct exposure to the sand/dust environment. (10) Record still photo or video images of the test setup, operations, and results as required. Figures 3, 4, and 5 show example test configurations. If required, collect, quantify, and characterize particle size and amount of sand that penetrates the UUT. This may be accomplished by thoroughly sweeping or vacuuming the interior spaces to collect the material and characterizing as described in Appendix B. b. Sand and Dust Test. Conduct this test following the procedure outlined above (paragraph 4.2.a) but substituting a mixture of sand and dust.

The dust is pre-mixed with the sand in a separate mixer at the required concentrations. See Appendix A, Table A-2 for example parameter configurations. Figure 3. Typical Outdoor Sand and Dust Test 9