US Army Developmental Test Command TOP 1-2-621 — REPORT DOCUMENTATION PAGE

Downloaded from https://www.everyspec.com TOP 1-2-621 6 February 2009 3.5 Safety Requirements. a. Follow the local Safety Standing Operating Procedure (SSOP) when conducting operations with explosive components. An example may be found in ATC SOP 385-2386 a . Personnel involved in test operations shall be thoroughly aware of the hazards and take appropriate precautions to conduct operations in a safe manner. b. Sand and dust mixtures may contain carcinogens or be otherwise hazardous to human health. Refer to the supplier's Material Safety Data Sheet (MSDS) or equivalent for health hazard data; e.g., exposure to silica can cause silicosis; other material may cause adverse health effects.

Utilize the appropriate personal protection equipment such as masks, full face shields, hazardous material suit, etc. c. The relatively dry test environment combined with the moving air and organic dust particles may cause a buildup of electrostatic energy that could affect operation of the test item. Use caution when making contact with the test item during or following testing if organic dust is used, and be aware of potential anomalies caused by electrostatic discharge during test item checkout. d.

For tests in which temperature conditioning is interrupted because of work schedules, etc., maintaining the test item at the test temperature for the time required will facilitate completion of the test when resumed. If the temperature is changed, before continuing the test, re-stabilize the test item at the temperature of the last successfully completed period before the interruption. Caution: When soaking at high temperature, e.g., overnight, ensure the total test time at the most severe temperature does not exceed the life expectancy of any material. 4. TEST PROCEDURES. 4.1 General. a.

The primary objective of this test is to ensure test item performance is within system specification; i.e., successfully withstands the exposure to a sand and dust environment. Some systems specify particle concentration levels targeted to meet system deployment areas. Others will specify the values of MIL-STD-810 which are as follows: (1) Blowing Sand. For systems likely to be used close to helicopters operating over unpaved surfaces, use 2.2 ± 0.5 g/m 3 (0.06 ± 0.015 g/ft 3 ). For systems never used or exposed in the vicinity of operating aircraft, but which may be used or stored unprotected near operating surface vehicles, use 1.1 ± 0.3 g/m 3 (0.033 ± 0.0075 g/ft 3 ).

For systems that will be subjected only to natural conditions, use 0.18 g/m 3 -0.0/+0.2 g/m 3 (0.005g/ft 3 ). (2) Blowing Dust. The dust concentration is 10.6 ± 7 g/m 3 (0.3 ± 0.2 g/ft 3 ) unless otherwise specified. This concentration exceeds that normally associated with moving vehicles, aircraft, and troop movement, but has historically proven to be a reliable concentration for blowing dust tests. 7