Delta Electronics — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM 1. Range: 0 ~ +2,147,483,647 2. Unit: machine unit (cm/min, 10deg/min, inch/min). The unit setting can be modified by b0 and b1 of D1816 (D1896, D1976). Please see Appendix in Chapter 14 for details. 1. When b5 of D1846 (D1926, D2006) is ON, MPG input operation will be enabled. 2. Users can generate A/B phase input pulse by MPG. See the figure below for the relation between input and output pulses. Servo Drive A-phase D1858(D1938) D1859(D1939) Input pulse x FP Servo Motor = Output pulse RP B-phase 3. If LSP is enabled during the operation, the forward pulse will be disabled but reverse pulse will be enabled.

If LSN is enabled during the operation, the reverse pulse will be disabled but forward pulse will be enabled. 4. The output frequency is the multiplication result between MPG input pulses and the electronic gear ratio. (D1858 (D1938, D2018), D1859 (D1939, D2019)).

DVP-PM Application Manual 3-75 X axis Y axis Z axis A axis Execution Status HW LW HW LW HW LW HW LW D1856 D1936 D2016 D2096 bit# D1856 (D1936, D2016) bit# D1856 (D1936, D2016) 0 Forward pulse output in progress 8 Not defined 1 Reverse pulse output in progress 9 Not defined 2 Operation in progress 10 Not defined 3 Error occurs 11 Not defined 4 Operation pauses 12 Not defined 5 Forward MPG input 13 Not defined 6 Reverse MPG input 14 Not defined 7 Not defined 15 Not defined X axis Y axis Z axis A axis Error Code HW LW HW LW HW LW HW LW D1857 D1937 D2017 2097 X axis Y axis Z axis A axis Electronic Gear Ratio HW LW HW LW HW LW HW LW D1858 D1938 D2018 D2098 Numerator of electronic gear ratio D1859 D1939 D2019 D2099 Denominator of electronic gear ratio