Delta Electronics — 3.12.2 Manual Modes

3 Functions of Devices in DVP-PM 3.12.2 Manual Modes 1. There are 8 manual modes in DVP-PM 1. Mechanical zero return 6. 2-speed positioning 2. JOG mode 7. 2-speed positioning interruption 3. Single-speed positioning 8. Variable speed mode 4. Single-speed positioning interruption 9. MPG input 5. Externally triggering single-speed positioning* Note*: Only DVP-20PM supports this function 2. When several manual modes are enabled at the same time, they will be processed in the following order. 1. STOP 7. Single-speed positioning 2. Mechanical zero return 8. Single-speed positioning interruption 3. JOG+ mode 9. Externally triggering single-speed positioning 4. JOG- mode 10. 2-speed positioning 5.

MPG input 11. 2-speed positioning interruption 6. Variable speed mode When one of the manual modes is being executed and another manual mode is enabled, DVP-PM will remain the operation of the executing manual mode. 3. There are two types of pulse acceleration/deceleration curves. 1. Trapezoid curve 2. S curve DVP-PM Application Manual 3-77