Mitsubishi — 5.6 Application Instructions

5 Categories and Use of Basic Application Instructions *1: Y1 is dual output. When M0 is OFF, Y1 is controlled by M1. When M0 is ON, Y1 is controlled by M12. DVP-PM Operation Instruction 5-16 Contact state Contact state Output coil state Device before CJ execution during CJ execution during CJ execution Y, M, S M1, M2, M3 OFF M1, M2, M3 OFF t ON Y1*1, M20, S1 OFF M1, M2, M3 ON M1, M2, M3 ON t OFF Y1*1, M20, S1 ON 10ms Timer M4 OFF M4 OFF t ON Timer T0 is not enabled. M4 ON M4 ON t OFF Timer T0 immediately stops and is latched. When M0 ON t OFF, T0 will be reset. M6 OFF M6 OFF t ON Timer T240 is not enabled. M6 ON M6 ON t OFF Timer T240 immediately stops and is latched.

When M0 ON t OFF, T240 will be reset. C0 ~ C234 M7, M10 OFF M10 is ON/OFF triggered Counter C0 stops M7 OFF, M10 is ON/OFF triggered M10 is ON/OFF triggered Counter C0 stops and latched. When M0 is OFF, C0 resumes counting. Application instruction M11 OFF M11 OFF t ON Application instructions will not be executed. M11 ON M11 ON t OFF The skipped application instruction will not be executed but API 53~59, API 157~159 keep executing.