Mitsubishi — 5.6 Application Instructions

5 Categories and Use of Basic Application Instructions API 111 Operands: S 1 : Lower bound of zone comparison S 2 : Upper bound of zone comparison S : Comparison value D : Comparison result Explanations: 1. The data of S is compared to the data range of S 1 ~ S 2 and the result ( > , = , < ) is indicated by three bit devices in D 2. D occupies 3 consecutive devices. 3. F refers to floating point input. Be sure to add a decimal point when using it. 4. Only 32-bit instructions DEZCP and DEZCPP are applicable. 5. If S 1 or S 2 is specified with floating point value F, the instruction will operate in binary floating point. 6. Operand S 1 should be smaller than operand S 2.

When S 1 > S 2 , the instruction takes S 1 as the 1 st comparison value and performs normal comparison similar to ECMP instruction. Program Example: 1. If the specified device is M10, M10~M12 will automatically be used. 2. When X0 = ON, one of M10~M12 will be ON. When X0 = OFF, DEZCP instruction is not executed, M10~M12 will retain their previous state before X0 = OFF. 3. RST or ZRST instruction is required if users need to reset the comparison result. X0 M10 M10 = ON when (D1,D0)>(D21,D20) M11 M11 = ON when (D1,D0) (D21,D20) M12 M12 = ON when (D21 D20)>(D11,D10) , Points to note: For floating point operations, see “5.3 Numeric Values for Data Processing”.

DVP-PM Application Manual 5-95 Mnemonic Operands Function Controllers 20PM 10PM D EZCP P Floating Point Zone Compare Type OP Bit Devices Word Devices Program Steps X Y M S F H KnX Kn Y KnM KnS T C D V Z D S 1 * * S 2 * * S * * D * * * DEZCP D0 D10 D20 M10