5 Categories and Use of Basic Application Instructions Operands: S : Source device (binary floating value) D : Operation result Explanations: 1. COSH value = ( e s +e -s ) / 2. COSH instruction performs hyperbolic-cosine operation on S and stores the result in D 2. F refers to floating point input. Be sure to add a decimal point when using it. 3. Only 32-bit instructions DCOSH and DCOSHP are applicable. 4. Flags: a) If the absolute value of the result exceeds the max floating point value, carry flag will be ON. b) If the absolute value of the result is less than min. floating point value, borrow flag will be ON. c) If the conversion result is 0, zero flag will be ON. Program Example:
When X0 = ON, DCOSH instruction performs hyperbolic-cosine operation on the binary floating value in (D1, D0) and stores the COSH value in (D11, D10) in binary floating format. X0 Binary floating point COSH value binary floating point Points to note: For floating point operations, see “5.3 Numeric Values for Data Processing.”. DVP-PM Operation Instruction 5-120 API Mnemonic Operands Function Controllers 20PM 10PM 137 D COSH P Hyperbolic Cosine Type OP Bit Devices Word Devices Program Steps X Y M S F H KnX KnY KnM KnS T C D V Z D S * * D * OX O100 Z ero flag M1808 M1968 B orrow flag M1809 M1969 C arry flag M1810 M1970 DCOSH D0 D10 D 1 D 0 D 11 D 10