Mitsubishi — 5.6 Application Instructions

5 Categories and Use of Basic Application Instructions API D 174 Operands: S 1 : Floating point multiplicand S 2 : Floating point multiplicator D: Product Explanations: 1. DMULR instruction multiplies S 1 with S 2 and stores the operation result in D . 2. In DMULR instruction, floating point values can be directly entered into S 1 and S 2 . 3. In DMULR instruction, floating point values (e.g. F1.2) can be either entered directly into S 1 and S 2 or stored in data registers for operation. 4. When S 1 and S 2 is specified as data registers, the function of DMULR instruction is the same as API 122 EMUL instruction. 5. S 1 and S 2 can designate the same register.

In this case, if the instruction is specified as “continuous execution instruction” (generally DMULRP instruction) and the drive contact is ON, the register will be multiplied once in every scan 6. Flags: If absolute value of the result exceeds max floating point value, carry flag will be ON. If absolute value of the result is less than min. floating point value, borrow flag will be ON. If the conversion result is 0, zero flag will be ON Program Example 1: When X0 = ON, multiply floating point number F1.200E+0 (Input F1.2, and scientific notation F1.200E+0 will be displayed on ladder diagram.

Users can set monitoring data format as float on the function View) with F2.200E+0 and store the obtained result F2.640E+0 in register D10 and D11 . X0 Program example 2: When X1= ON, multiply the floating point value (D1, D0) with (D11, D10) and store the result in (D21, D20). X1 DVP-PM Operation Instruction 5-124 Operands Function Controllers 20PM 10PM MULR P Floating point multiplication Type OP Bit Devices Word devices Program Steps X Y M S F H KnX KnY KnM KnS T C D E F DMULR, DMULRP: 13 steps S 1 * S 2 * D * OX O100 Zero flag M1808 M1968 Borrow flag M1809 M1969 Carry flag M1810 M1970 DMULR F1.200E+0 F2.200E+0 D10 DMULR D0 D10 D20