6 Motion Instructions & G-Code Instructions MON 08 Explanations: 1. You can place an M-Code instruction after SETR 2. When SETR is executed, you can set the current position of X/Y/Z axis as the electrical zero point, i.e. move the content in the current position (CP) register into the register for electrical zero point. Program Example: . . . Subroutine OX0 . . . SETR Remarks: Relevant special registers DVP-PM Application Manual 6-26 Mnemonic Operands Function Controllers SETR N/A Set up Electrical Zero Point 20PM - D1848 Current position of X axis: CP (low word) D1849 Current position of X axis:

CP (high word) D1866 Electrical zero point address on X axis (low word) D1867 Electrical zero point address on X axis (high word) D1928 Current position of Y axis: CP (low word) D1929 Current position of Y axis: CP (high word) D1946 Electrical zero point address on Y axis (low word) D1947 Electrical zero point address on Y axis (high word) D2008 Current position of Z axis: CP (low word) D2009 Current position of Z axis: CP (high word) D2026 Electrical zero point address on Z axis (low word) D2027 Electrical zero point address on Z axis (high word)