Mitsubishi — 6.3 Motion Instructions

6 Motion Instructions & G-Code Instructions Program Example: 1. When X0 = ON, DINTR instruction in OX0 subroutine will be executed. Y axis accelerates to the first speed 250kHz in 100ms and operate at the speed stably. When DOG signal is triggered, it will further accelerate to the second speed 500kHz, and finish the double speed positioning on Y axis with the additional 500,000 pulses. 2. When X0 = OFF, program OX0 and DINTR instruction will be disabled. X0 X0 Subroutine OX0 Remarks: Relevant special registers DVP-PM Application Manual 6-32 MOVP H8000 D1868 SET M1074 RST M1074 BRET MOVP K100 D1916 MOVP K100 D1917 DINTR YKK500000 FKK250000 FKK500000 D1836 Acceleration time of X axis:

T ACC D1837 Deceleration time of X axis: T DEC D1848 Current position of X axis: CP (low word) D1849 Current position of X axis: CP (high word) D1916 Acceleration time of Y axis: T ACC D1917 Deceleration time of Y axis: T DEC D1928 Current position of Y axis: CP (low word) D1929 Current position of Y axis: CP (high word)