6 Motion Instructions & G-Code Instructions MON 19 Operands: P 1 : Current position on X axis P 2 : Current position on Y axis P 3 : Current position on Z axis Explanations: 1. When SETT instruction is executed, the current position set in SETT instruction will be written automatically into current position registers: D1848 ~ D1849 for X axis; D1928 ~ D1929 for Y axis and D2008~D2009 for Z axis. 2. Range of parameters: (16-bit) K = -32,768 ~ 32,767; H = 0 ~ FFFF; D = 0 ~ 9,999; (32-bit) KK = -2,147,483,648 ~ 2,147,483,647; HH = 0 ~ FFFFFFFF; DD = 0 ~ 9,998. 3. The 16-bit devices and 32-bit devices can be used together. 4.

Due to that current position is changed when SETT instruction is executed, the mechanical zero point and electrical zero point will also be changed. 5. At least one current position on one axis should be specified, therefore there are 7 operand combinations for SETT instruction. Program Example: Subroutine OX0 X Current position (1000, 1000) Current position (100, 100) X (500, 500) (-400, -400) SETT execution Y Y DVP-PM Application Manual 6-38 Mnemonic Operands Function Controllers 20PM - SETT X P Y P Z P 1 2 3 Set up Current Position Controllers 20PM - Type Bit Devices Double-Word Devices Notes K H D KK HH ƒ SETT instruction supports V, Z index register modification on the devices.

ƒ See specifications of DVP-PM for the applicable range of each device. ƒ You can place an M-Code instruction after SETT. P 1 * * * * * P 2 * * * * * P 3 * * * * * NO. Instruction Operand combination 20D 20M 1 SETT X P 1 9 9 2 Y P 2 9 9 3 X P Y P 1 2 9 9 4 Z P 3 - 9 5 X P Z P 1 3 - 9 6 Y P Z P 2 3 - 9 7 X P Y P Z P 1 2 3 - 9 SETT X100 Y100