Delta Electronics — 6.5 G-Code Instructions

6 Motion Instructions & G-Code Instructions 6.5 G-Code Instructions G-Code Operands: P 1 : Target position on X axis P 2 : Target position on Y axis P 3 : Target position on Z axis (built-in 3 rd axis) Explanations: 1. For 20D model, the target position on Z axis ( P 3 ) is operated by the built-in 3 rd axis control. Please refer to p6-46. 2. Range of parameters: -2,147,483,648 ~ 2,147,483,647 (without decimal point); -2,147,483.648 ~ 2,147,483.647 (with decimal point) 3. The operand parameters for 20M model can also be 16-bit register (D) or 32-bit register (DD). 4. For relevant special registers, see Remarks of MON 00 DRV. 6. The settings of position have continuity. See Remarks. 5.

The moving speed of G00 instruction is fixed at maximum speed V MAX . 7. Acceleration/deceleration time and bias speed can be set up in special D. 8. Acceleration/deceleration time and bias speed increase or decrease in proportional to the setting of V MAX . 9. Timing diagram: Speed Moving at V MAX Number of output pulses Bias speed Time Deceleration time Acceleration time 10. 20D model does not support 3-axis positioning control. For 3 rd axis control, an additional single-axis positioning module DVP-01PU is required. Therefore, you have to design a 2-axis high-speed positioning in X-Y axis and independent high-speed positioning for Z axis.

For the safety of the mechanical operation, when G00 instruction is executed, Z-axis high-speed positioning will be executed first before the X-Y-axis high-speed positioning. That is to say, when DVP-PM is executing G00 instruction with X-Z, Y-Z, X-Y-Z combinations, the program will automatically be divided as: G00 Z P 3 (A) G00 X P 1 Y P 2 (B) See Remarks for more explanations on row (A) and (B) Remarks: 1. The settings of position have continuity, for example: G00 X500.0 Y500.0 Z500.0; X1000.0 Y1000.0 Z1000.0; After the row with G00 instruction is executed, the program will execute the next row.

The second row of the DVP-PM Application Manual 6-44 Mnemonic Operands Function Controllers 20PM - G00 X P Y P Z P 1 2 3 3-axis High-speed Positioning Controllers 20PM -