7 Use DVP-PM As Slave When X0 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable JOG+ operation on X axis in Slave. When X1 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable JOG- operation on X axis in Slave. When X2 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable zero return on X axis in Slave. When X3 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable single-speed positioning on X axis in Slave. When X4 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable 2-speed positioning on X axis in Slave.
When X5 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable single-speed positioning with additional distance on X axis in Slave. When X6 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable 2-speed positioning with additional distance on X axis in Slave. When X7 = ON, write in CR#1 of Slave, corresponding to D1501 in Slave, to enable MPG input operation of X axis in Slave. When X0 ~ X7 = OFF, write in CR#1 of Slave, corresponding to D1501 in Slave, to STOP X axis in Slave.
DVP-PM Application Manual 7-3 X0 TOP K0 K1 H6 K1 X1 TOP K0 K1 HA K1 X2 TOP K0 K1 H42 K1 X3 TOP K0 K1 H102 K1 X4 TOP K0 K1 H402 K1 X5 TOP K0 K1 H202 K1 X6 TOP K0 K1 H802 K1 X7 TOP K0 K1 H22 K1 X0 TOP K0 K1 H1 K1 X1 X2 X3 X4 X5 X6 X7 END END TOP K0 K1 H6 K1 TOP K0 K1 HA K1 TOP K0 K1 H42 K1 TOP K0 K1 H102 K1 TOP K0 K1 H402 K1 TOP K0 K1 H202 K1 TOP K0 K1 H802 K1 TOP K0 K1 H22 K1 TOP K0 K1 H1 K1