Delta Electronics — 8.1.2 Design Procedure

8 Application Examples Example of motion instructions for trajectory 3 P0 P0 subroutine INCT Set up relative position DRV X-25000 Y25000 Fast move to designated position LIN X50000 Y0 F20000 Move to designated position by linear interpolation. LIN X-25000 Y60000 F20000 Move to designated position by linear interpolation. Can also be written as LIN X-25000 Y60000 LIN X-25000 Y-60000 F20000 Move to designated position by linear interpolation.

Can also be written as LIN X-25000 Y-60000 DRV X25000 Y-25000 Fast move to designated position SRET Example of G-code instructions for trajectory 3 P0 P0 subroutine G91 Set up relative coordinate G00 X-25.0 Y25.0 Fast move to designated position G01 X50.0 Y0 F20.0 Move to designated position by linear interpolation. G01 X-25.0 Y60.0 F20.0 Move to designated position by linear interpolation. Can also be written as G01 X-25.0 Y60.0 G01 X-25.0 Y-60.0 F20.0 Move to designated position by linear interpolation.

Can also be written as G01 X-25.0 Y-60.0 G00 X25.0 Y-25.0 Fast move to designated position SRET Example of motion instructions for trajectory 4 P0 P0 subroutine ABST Set up absolute coordinate DRV X10000 Y10000 Fast move to designated position LIN X10000 Y30000 F20000 Move to designated position by linear interpolation. Can also be written as LIN Y30000 F20000 CCW X10000 Y110000 J40000 F20000 Move to designated position by arc interpolation. Can also be written as CCW Y110000 J40000 CW X10000 Y230000 R60000 F15000 Move to designated position by arc interpolation. Can also be written as CW Y230000 R60000 F15000 LIN X10000 Y210000 F15000 Move to designated position by linear interpolation.

Can also be written as LIN Y210000 CCW X10000 Y130000 J-40000 F15000 Move to designated position by arc interpolation. Can also be written as CCW Y130000 J-40000 CW X10000 Y10000 R60000 F20000 Move to designated position by arc interpolation. Can also be written as CW Y10000 R60000 F20000 SRET DVP-PM Application Manual 8-5