8 Application Examples Ladder diagram: Operations: G0G90X1.759Y87.87 G1Z0.0F19.4 . . . G-Code (NC-Code) which draws trajections G0X56.164Z5.0 When the program sections 1 ~ 4 are completed, drawing of letters, graphs or any texts by DVP-PM can be performed by DVP-PM 8.3 Planning Variable Speed Operation This section introduces how to trigger many segments of speed (variable speed) in a fixed route by using single-speed positioning mode. 8.3.1 Program structure 1. Trigger condition 1: external input signal. X0 ~ X3 switches to the 2 nd ~ 5 th speed. 2. Trigger condition 2: comparison results of CP. M0 ~ M3 switches to the 2 nd ~ 5 th speed. 3. Trigger condition 3: Timer.
T0 ~ T3 switches to the 2 nd ~ 5 th speed. Frequency (Hz) T ACC T DEC T ACC T ACC T DEC T DEC V BIAS Time (ms) Number of pulses in Segment 1 Number of pulses in Segment 2 Number of pulses in Segment 3 Number of pulses in Segment 4 Number of pulses in Segment 5 Start X7 X0 X1 X2 X3 Trigger condition 1 Trigger condition 2 M0 M1 M2 M3 Trigger condition 3 T0 T1 T2 T3 DD1838 (total number of output pulses) = number of pulses in Segment 1 + Segment 2 + … + Segment 5 DVP-PM Application Manual 8-10