Mitsubishi — 9.3 Explanations on Special Flags and Registers

9 Electrical CAM D1832 = 0 Slave position D1832 = 1 Start0 / PG0 Master position Slave position Start0 / Pg0 Master position „ Distribution of remaining acyclic E-CAM pulses: D1833 Assume that Master operates 202 pulses and a single E-CAM Data requires 50 pulses, the execution results will be 4 cycles of E-CAM Data and 2 pulses remaining. In this case, set D1832 = 4(repeat for 4 times) and D1833 = 2. DVP-PM will execute one more pulse at the first and second intervals between the repeated E-CAM Data cycles, so as to properly distribute the remaining pulses. E-CAM Data in this condition will operate 5 times and only the first and the second cycle will be added with one more pulse as below.

Note: The value in D1833 should be smaller or equal to D1832. D1832 = 4, D1833 = 2 Slave position N N N N+1 N+1 Master position Start0 / Pg0 D1832 = 4, D1833 = 3 In the same way, DVP-PM will execute one more pulse at the 1 st , 2 nd and 3 rd intervals between the repeated E-CAM Data cycles, so as to properly distribute the remaining pulses. Slave position Master position N N N+1 N+1 N+1 Start0 / Pg0 „ Pulses for delay start of acyclic E-CAM: D1834 The execution of acyclic E-CAM Data can be delayed by the number of pulses set in D1834. In diagram below, when PG0/START0 is triggered, E-CAM Data delayed for 10 or 50 pulses before its execution. DVP-PM Application Manual 9-18