Delta Electronics — 9.3 Explanations on Special Flags and Registers

9 Electrical CAM Slave Stop at DOG signal Acyclic E=CAM D1863, D1862 Master CLR0 M1813 Reset by user Set by system DOG0 On Slave Master CLR0 M1813 Master „ Switch the source of Master of acyclic E-CAM For acyclic E-CAM, the source of Master can be switched to Y axis during the execution by setting up M1755. With M1755 = ON, source of Master will be switched automatically when Master position (DD1862) is bigger than the switching position (DD1866). Source of Master will be switched back to MPG0 after acyclic E-CAM cycle is completed. (Not applicable for virtual Master mode: M1909 / M1910 ).

The function is generally used for obtaining equalled deceleration speed as well as correct stop position, regardless of the error resulted from Master speed or the characteristics of photo sensor. M1755=ON Slave speed Master position Switching position of source of Master (D1867,D1866) „ Remain current speed until meeting limit switch: M1757 When M1757 is ON, Slave will remain current speed and continue operation until the right/left limit is reached. DVP-PM Application Manual 9-20 is ON N times Master speed N times Y axis speed