9 Electrical CAM There are 4 parts in CAM Chart: Displacement / Degree (relative position of Master/Slave), Velocity / Degree (relative speed of Master/Slave), Acc Speed / Degree (relative acceleration speed of Master/Slave), and Data Setting Area in the bottom. „ The first 3 charts indicate user-defined E-CAM Data with horizontal axis as Master position, and vertical axis as Slave position, speed ratio of Slave/Master, and acc speed ratio of Slave/Master. „ Data Setting Area: 1. Displacement Resolution: set up E-CAM Data resolution. Set range:10~2048 points. 1 point of E-CAM Data occupies 10 steps of user program area (Total 64k steps).
Max 2048 points can be set up for a CAM Chart as below. DVP-PM Application Manual 9-22