Mitsubishi — 9.4.2.2 Smooth Curve Interpolation

9 Electrical CAM as below. For the set up methods please refer to section 9.4. Step 2: Set the resolution of E-CAM Chart-0. The resolution should be equal or bigger than “Original data points + Total points to be inserted.” Step 3: Set M0 to write the parameters for smooth curve interpolation into registers D100~D105 Step 4: Set M1 to write in the data in D100~D105 for executing smooth curve interpolation. Step 5: Execute the program and monitor the E-CAM curve in E-CAM Chart-0. The curves after interpolation will be as below: Ladder Diagram:

M0 M1 DVP-PM Application Manual 9-38 X Y x y x y x y 0 0 6 -68.332 12 -93.672 18 -22.86 1 -0.036 7 -70.44 13 -92.556 19 -0.396 2 -0.288 8 -70.98 14 -91.224 20 0.288 3 -47.196 9 -70.052 15 -91.152 21 0.072 4 -62.604 10 -70.756 16 -91.044 22 0 5 -65.16 11 -71.496 17 -46.08 23 0.036 MOV K10003 D0 DMOV K10000 D100 MOV K23 D102 MOV K400 D103 MOV K5 D104 MOV K0 D105 DTO K100 D0 D100 K5