9 Electrical CAM .. Set up M4 to calculate the actual offset value and the modified Slave length M4 Convert the offset value into floating point value D142=1/2 D138 Users can decide an offset ratio Backup the actual offset value .. M4 Calculate the modified Slave length according to the actual offset value .. M4 When calculation is finished, move the length of Slave into D302 back Points to note: 1. Users can modify the offset ratio (0.5*D138 ) according to actual needs 2.
D132 has to be applied in DTO instruction for creating rotary cut E-CAM Data with offset compensation in this example 9.4.2.6 Flying Saw Application – Check cutter position In flying saw application, it is important to check if the cutter is back in designated position when moving back. If the cutter is not at designated position, it should remain current speed until limit switch is met, otherwise the mechanical system might be damaged during the moving back process of cutter. M1757 can be applied to remain current speed of Slave and continue operation until the limit. Users can compare the designated position with Master position in current cycle to decide if M1757 needs to be enabled.
Master position in current cycle can be obtained by subtracting “Master position captured at the end of cycle” from accumulated Master position (DD1862). Master position captured at end of cycle can be read out by using DFROM instruction (D0 = K10005, Capture mode). „ Application Example Set up: Check if the cutter position is correct and automatically determine the execution of M1757. Control Steps: Step 1: Run the program and read the E-CAM status in capture mode by DFROM instruction. Read the data in CR#10005 (Capture mode) of special module K100 to D300~D308 at the end of cycle. Step 2:
Substract the captured Master position (D306) from the number of accumulated MPG input pulses (D1862), and we can obtain the actual Master position in current cycle (D350). Step 3: Compare the actual Master position (D350) with the target position (D1842). If the actual Master position is bigger than the target position and the limit switch has not been triggered, execute M1757 then stop the CAM operation. DVP-PM Application Manual 9-52 DFLT D138 D140 DEDIV D140 F2.0 D142 DINT D142 D144 DSUB D126 D144 D302 DMOV D126 D302