Mitsubishi — 9.6.2.2 Flying Saw

9 Electrical CAM Ж Ж According to the above E-CAM Chart, we can calculate the pulses per round of Slave (Slavemax=400) by the square measure of velocity data. [(1*100/2+1*(200-100)+1*(300-200)/2)] * 2 = 400 In addition, for pulses per round of Master you can apply input /output magnification setting at 9.3.1.7 in this chapter to obtain the proper set value. Different from the setting of rotary cut, lower/higher bound of E-CAM synchronized output section should be specified. Please refer to point 4 of 9.3.1.3 in this chapter. Also, to save the time of operation cycle you can set a higher speed for the process when cutter returns to position 4. See below example.

In this example, modify the angle of position 4 from 700 to 600 degrees and set the stroke at section 5 as -2, DVP-PM Application Manual 9-70