Mitsubishi — 11.2.2 Download by B Type HMI

11 G-code Application Step 1: set up an HMI supports G-code (NC file) download function. (1) HMI model: DOP-BS0722P00 (2) Install the HMI programming software: Screen Editor 2.00.12 (3) Execute Patch_DOPB_072909 to update the software version to Screen Editor 2.00.12 (4) Edit HMI program: (a) Execute Screen Editor 2.00.12, open a new file (b) Set up the parameters of control block as below: “Option” >> ”Configuration” >> ”Control Block” (c) Set up communication parameters as below: “Option” >> ”Configuration” >> “Communication” Controller: Delta PM RTU COM: COM1/COM2/COM3 Interface: RS232/RS485 Data Bits: 8(RTU) Stop Bits: 1 Baud Rate: 9600/19200/38400/57600/115200 Parity:

None (5) Set the path to enter G-code download window: write 65535 into HMI internal memory address $0 and the G-code download window will be displayed. There are 2 ways to set up the path: DVP-PM Application Manual 11-9