Delta Electronics — 11.3.1 Operation steps

11 G-code Application download by monitoring D3000. LD= D3000 0xFFFF Y0 Step 6: When the values in D3002 and D3003 are both 20H (K32), the complete recipe download process are finished. Check the completed conversion results by To instruction as below. M27 LD= D3002 K32 LD= D3002 K32 11.3 G-code Application in Dispensers For G-code application in automatic dispensors, DVP-PM00M provides a specific function which performs smooth movement with equal speed, avoiding pauses which lead to uneven dispensing results during operation. The function utilizes CAM charts for storing the G/M codes and applys E-CAM operation to execute the data in CAM charts.

DVP-PM are designed with three CAM charts storing 3 sets of G/M code programs including OX0, OX1 and OX2. Max 2048 points are allowed for each CAM chart, and each CAM chart should accommodate displacement and speed data of 3 axes. In addition, only G00, G01, G04 and M codes applied in “With mode” are supported in this function. Therefore, the total available instruction capacity for G-codes (G00/G01/G04) and M-codes in single CAM chart is 680, excluding the begginging and ending instructions. 11.3.1 Operation steps The 4 operation steps are 1. parameter setting on servo, 2. Create a blank CAM chart, 3. Load data into CAM chart and 4. Enable the dispensing operation. 1.

Parameter setting on servo: if a Delta’s servo is applied, set the parameter p1-08 as 5~8 according to the mechanism. 2. Create a blank CAM chart: create a blank CAM chart with proper resolution. For example, if OX0 for dispensing operation requires 500 points including G04 and M-codes, the resolution of CAM chart-0 should be set as 1506 as below. The same rule also applies on OX1 and OX2. DVP-PM Application Manual 11-17 RST M24 TO K255 K1 K0 K1 RST M27 RST M24