13 CANopen Communication Card 13.1 Introduction to DVP-FPMC: CANopen Communication Card DVP-FPMC is a CANopen communication card for DVP-PM series PLC to conduct data exchange, featuring: ‹ Compliant with CANopen standard protocol, DS301 v4.02 ‹ Supports NMT protocol ‹ Supports SDO protocol ‹ Supports CANopen standard protocol DS402 v2.0: Max.
4 motion axes ‹ The motion axes support Profile Position mode 13.2 Specifications „ CANopen connector „ Ethernet connector „ Communication „ Electrical specification DVP-PM Application Manual 13-1 Transmission CAN method 500VDC Electrical isolation Removable connector (5.08mm) Type 2 communication cables, 1 shielded cable and 1 ground wire Transmission cable Transmission Ethernet method 500VDC Electrical isolation Removable connector (5.08mm) Type 2 communication cables, 1 shielded cable and 1 ground wire Transmission cable PDO, SDO, SYNC (synchronous object), EMCY (emergency object), NMT, Heartbeat Protocol type Serial transmission 500k, 1M bps (bits per second) speed 254 Product code 0(Non-Profile) Equipment type 477 (Delta Electronics, Inc.) Company ID Supplied by MPU through internal bus, 24VDC (-15% ~ 20%) Power supply voltage