13 CANopen Communication Card 2. Set A2 Keypad P3-00 as 0x01~0x04 (Node ID of servo drives) 3. Set up A2 Keypad P3-01 as 0x0403(1M bps) for baud rate setting. (2: 500 kbps; 4: 1Mbps) DVP-FPMC currently supports communication speed up to 1M (default) and 500k. z DVP-FPMC settings When all parameter settings for CANopen in connected drives are completed, create a CANopen network by DVP-FPMC as below: 1. Set the content of CR#500 as 1 to set up DVP-FPMC in A2 mode. 2. Set up CR#053 for DVP-FPMC node ID setting. Default: 127 3. Set the content of CR#010 as H’FFFF to scan all connected drives. 4. Read the content of CR#010 by FROM instruction to check if the content is cleared. 5.
Set the content of CR#050 as 1 to set On all connected drives. Step 2 ~ step 4 can be performed on PMSoft. Right click at the icon of DVP-FPMC in the column of System Information, select All Scan and the connected drives will be displayed under DVP-FPMC. Please see the steps below for further setting. 1. Right click at DVP-FPMC icon and select All Scan. 2. Display the connection status of nodes after the scan is completed. 3. Right click at DVP-FPMC and select All Servo On. When the connected servos are enabled, a confirmation message will pop up. In addition, servo running status will be added after each node. DVP-PM Application Manual 13-22