Mitsubishi — 14.1 High Speed Compare and Capture Function

14 High Speed Compare and Capture (2) Setting format of control registers (CRn) for high-speed Capture function DVP-PM Application Manual 14-2 3 Y3 Y3 4 Reset C200 Reset C200 5 Reset C204 Reset C204 6 Finish Lead state of CAM Reset C208 7 Engage CAM Reset C212 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Setting s Tr igger sw itch of C apture function Output ter mi nals and coun te rs Output action C apture function D ata so urce of C apture function Bit SV 20PM 10PM Data source for capture function [3-0] 0 CP of X axis CP of X axis 1 CP of Y axis CP of Y axis 2 CP of Z axis CP of Z axis 3 C200 count value CP of A axis 4 C204 count value C200 count value 5 - C204 count value 6 - C208 count value 7 - C212 count value Capture function [5-4] 0 Default:0 Output action [7-6] 0 - No action 1 - 2, - Set 3 - Reset Output terminal and counters [11-8] 0 - Y0 1 - Y1 2 - Y2 3 - Y3 4 - Reset C200 5 - Reset C204 6 - Reset C208 7 - Reset C212 Trigger switch of Capture function [15-12] 0 X axis PG0 X0 1 X axis MPGB X1 2 X axis MPGA X2 3 X axis LSN X3 4 X axis LSP X4 5 X axis DOG X5