Mitsubishi — 3.11 Functions of Special Auxiliary Relays and Special Registers

3 Functions of Devices in DVP-PM D1834 = 10 D1834 = 50 Function Group: Operation Commands for X-Y-Z-A Axis Number: D1846, D1926, D2006, D2086 Explanations: Operation commands for X axis: D1846, Y axis: D1926, Z axis: D2006 and A axis: D2086 *Note: 1. MPG input for 00D: X axis (A0+/A0-, B0+/B0-), Y axis (A1+/A1-, B1+/B1-) MPG input for 00M: X axis (A0+/A0-, B0+/B0-), Y axis and Z axis (A1+/A1-, B1+/B1-) 2. Only bit 7 of D1926 supports the mode “Externally triggering single-speed positioning.” 3. Only bit 13 and bit 14 of D1846 support the CAM enabling function. Function Group: Work Modes of X-Y-Z Axis Number: D1847, D1927, D2007 Explanations: Work mode setting of X axis: D1847, Y axis:

D1927 and Z axis: D2007. DVP-PM Application Manual 3-53 bit# X-Y-Z-A operation setting bit# X-Y-Z-A operation setting 0 STOP 8 Enabling single-speed positioning mode START Enabling single-speed positioning with additional distance 1 9 2 JOG+ operation 10 Enabling 2-speed positioning mode JOG- operation Enabling 2-speed positioning with additional distance 3 11 4 Enabling variable speed operation 12 0: Stop OX; 1: Start OX 5* MPG input operation 13* Enabling cyclic CAM 6 Enabling zero return mode 14* Enabling acyclic CAM Externally triggering single-speed positioning - 7* 15 bit# Work mode of X-Y-Z bit# Work mode of X-Y-Z 0 - 8 MASK selection